DDC2 / 4-RS Wiring 
Digital Display Wall Clock Guide 
Page 22 
3-Wire Synchronous (115VAC) 
H
M
BLU / WHT
Run
BRN / WHT
BLK
BLK
Correction
AC Return
115VAC 
From 
Master Clock 
       To  
Other Clocks
6
7
8
Clock will correct minutes hourly at HH:59 and 
hour and minutes twice daily at 5:59. 
Wiring applies to secondary wall clocks such as: 
 
Lathem type SS  Cincinnati D10  IBM 77 Series 
 
Simplex 77 Series, 93-9, 91-9, 941-9, 943-9 
 
Stromberg 3000 
  Set switches 1-5 of S1 as shown. 
 
 Indicates depressed side of switch 
OPEN
1 2
3
4
5