Fujitsu RX900 S1 사용자 설명서

다운로드
페이지 368
366
Maintenance Manual
 RX900 
S1
Appendix
*1) The SAS RAID controller shall not be installed in PCIe slot #1 to #7 on the 
PCI Riser when a BBU is connected because of limited length of the BBU cable.
*2) The Quad LAN card consumes twice as much I/O space as a standard 
expansion card because it includes a bridge within the card. If you install this 
card into slot#1 or slot#2, no I/O resource will be assigned to the onboard GbE 
controller.
Emulex 4G-FCx1 Gen 1x8 8
x
x
x
x
x
x
x
x
4G-FCx2 Gen  1x8 8
x
x
x
x
x
x
x
x
8G-FCx1 Gen 2x8 8
2
2
2
2
x
x
x
x
8G-FCx2 Gen 2x8 8
2
2
2
2
x
x
x
x
FCoE
Gen 2x8 8
2
2
2
2
x
x
x
x
Intel
GbEx1
Gen  1x4 8
x
x
x
x
x
x
x
x
x
GbEx2
Gen  1x4 8
x
x
x
x
x
x
x
x
x
GbEx4
Gen 1x4 8
3
3
3
3
x
x
x
x
10GbEx2 Gen 2x8 8
3
3
3
3
x
x
x
x
Chipset
IOH#3
IOH#4
Bus scan order
12 11 10 9
17 16 15 14 13
I/O space assigning order within 
the I/O Hub (IOH)
1
2
1
2
Hot-plug
y
y
y
y
n
n
n
n
n
Gen2  width
x8 x8 x8 x8 x8 x8 x8 x8 x4
Slot #
9
10 11 12 13 14 15 16 17
Vendor Type
PCIe
Max #
Table 8: Expansion card installation recommendation I/O Hubs IOH#3 and IOH#4