208
Chapter 7  Installing Hardware Options
■ SCSI ID and Order of Installation
The numbers and SCSI IDs of the 3.5-inch storage bays are as follows. 
The SCSI IDs for internal hard disk units are set automatically.
Install internal hard disk units in the following order.
table: Order of Internal Hard Disk Unit Installation
Number of channels
Order of installation
Standard drive cage (1ch)
Bay 1 
→ Bay 2 → Bay 3 → Bay 4 → Bay 5 → Bay 6
Upgrade kit 6 hard disks 2 channel 
(2x3)
Bay 1 
→ Bay 4 → Bay 2 → Bay 5 → Bay 3 → Bay 6
Internal hard disk unit bay conversion 
kit (2ch)
Bay 1 
→ Bay 2 → Bay 3 → Bay 4 → Bay 5 → Bay 6 → 
Bay 7 
→ Bay 8 → Bay 9
[Standard drive cage (1ch)]
[Rack mount type (1ch)]
Bay6 : ID=5
Bay5 : ID=4
Bay4 : ID=3
Bay3 : ID=2
Bay2 : ID=1
Bay1 : ID=0
[With Upgrade kit 6 hard disks 
 2 channel (2x3)]
Bay6 : ID=2
Bay5 : ID=1
Bay4 : ID=0
Bay3 : ID=2
Bay2 : ID=1
Bay1 : ID=0
ch1
ch0
[With internal hard disk 
 unit bay conversion kit]
Bay6 : ID=5
 CD-ROM/FDD
Bay5 : ID=4
Bay4 : ID=3
Bay9 : ID=2
Bay8 : ID=1
Bay7 : ID=0
Bay3 : ID=2
Bay2 : ID=1
Bay1 : ID=0
ch1
ch0
 CD-ROM/FDD
 CD-ROM/FDD
Bay6 : ID=5
Bay5 : ID=4
Bay4 : ID=3
Bay3 : ID=2
Bay2 : ID=1
Bay1 : ID=0
 CD-ROM/FDD