Chapter 9  Operation and Maintenance
Check date and time settings
The set date and time is invalid. Start the BIOS Setup Utility 
and then enter the current date and time. If the message still 
appears, the keyboard must be replaced. Refer to "Contact 
Information" in "Start Guide", and contact your maintenance 
engineer. 
Previous boot incomplete - Default 
configuration used
POST did not complete during the last startup. Be sure to 
perform the following operation. Failure to do so can result in 
the OS not starting or the server not operating correctly.
1. Start the BIOS Setup Utility.
2. From the [Exit] menu, select [Save Changes & Exit] and 
press the [Enter] key.
The message "Save configuration changes and exit 
now?" is displayed. 
3. Select [Yes] and press the [Enter] key.
The BIOS Setup Utility closes and the server restarts. 
Memory Size found by POST differed from 
EISA CMOS
EISA CMOS is abnormal. Power off the server and turn it back 
on. If the message still appears, the keyboard must be replaced. 
Refer to "Contact Information" in "Start Guide", and contact 
your maintenance engineer. 
CPU mismatch detected
The CPU frequency or the number of CPUs has changed.
 If the correct CPU is installed and the message is displayed, 
select [Yes] for the [Reset Configuration Data] setting under 
the [Advanced] menu of the BIOS Setup Utility. If the message 
still appears, the CPU or baseboard must be replaced. Refer to 
"Contact Information" in "Start Guide", and contact your 
maintenance engineer. 
Available CPUs do not support the same bus 
frequency- system halted
CPUs with varying frequencies are installed. Install the correct 
CPUs. If the message still appears, the keyboard must be 
replaced. Refer to "Contact Information" in "Start Guide", and 
contact your maintenance engineer. 
Diskette drive A error
The floppy disk drive is abnormal. Check to see whether the 
floppy disk drive cable is connected properly. Also check the 
settings of [Diskette A] or [Diskette B] from the [Main] menu 
of the BIOS Setup Utility.
Diskette drive B error
Incorrect Drive A - run SETUP
Incorrect Drive B - run SETUP
System Cache Error - Cache disabled
The system cache is abnormal. Power off the server and turn it 
back on. If the message still appears, check the error log and 
replace the CPU if it is at fault. Or the baseboard must be 
replaced. Refer to "Contact Information" in "Start Guide", and 
contact your maintenance engineer. 
System memory exceeds the CPU's caching 
limit
EISA CMOS not writable
Power off the server and turn it back on. If the message still 
appears, the keyboard must be replaced. Refer to "Contact 
Information" in "Start Guide", and contact your maintenance 
engineer. 
DMA Test Failed
Software NMI Failed
Fail-safe Timer NMI Failed
Verify CPU Frequency selection in Setup
The CPU is abnormal. Power off the server and turn it back on. 
If the message still appears, check the error log and replace the 
CPU if it is at fault. If the message still appears, the keyboard 
must be replaced. Refer to "Contact Information" in "Start 
Guide", and contact your maintenance engineer. 
table: List of POST Errors
Message
Description