Fujitsu TX200 사용자 설명서

다운로드
페이지 317
275
PRIMERGY TX200 S2 User’s Guide
9
O
p
eration
 a
nd 
Mainten
ance
■ Error Messages during Installation
The following error messages may appear during installation using ServerStart. Check the corrective 
action against the relevant error.
"WzDiskAdmin: System Error! ......................... , Last Error: Device 
preparations are not complete. " is displayed
Optional SCSI devices (e.g., hard disk cabinet or DAT unit) may be connected. Disconnect the optional 
SCSI devices and perform installation again. Connect the optional devices after the installation 
completes.
"WzDiskAdmin: Partition detected! Please delete all partition before starting 
Configuration" is displayed 
Run the guided or preconfiguration mode again. Check [Delete all partitions on the displayed disk] in 
the disk wizard.
"WzRaid: RAID arrays detected! Please delete all RAID arrays before starting 
Configuration" is displayed 
Use the ServerStart floppy disk you have created. Check [Delete existing RAID array] or select [Use 
existing array] in the RAID wizard.
"Operating System not found" appears when the system restarts after file 
copy from the CD-ROM 
The following problems should be considered. Check the settings.
• The array controller card comes later than the onboard SCSI in order of device startup.
• The Active flag is specified.
"Missing Operating System" appears during installation 
The installation partition size may be too large. Specify the installation partition size correctly. 
 For details on the installation partition size, refer to "2.3.1 Installation Partition Size" (
"Error 1920. Service (PXE Services) failed to start" appears during 
preconfigured installation 
The system installed with the preconfigured settings (PXE server) may not be connected to the network. 
Check the LAN cable connection and click [Rerun].