CHAPTER 10 Error Notification and Maintenance (Contents, Methods, and Procedures) 
10.2 Troubleshooting 
184 
 
C122-E175-01EN 
 
10.2.7 Problems related to the main unit or a PCI_Box 
This section describes problems related to the main unit or a PCI_Box. It also describes how to correct the 
problems. 
An LED on the main unit does not go on, or the orange LED is on. 
Cause: The main unit may have failed. 
Corrective action: Contact your sales representative or a field engineer. Before making contact, confirm 
the model name and serial number shown on the label affixed to the main unit. 
An error message appears on your display. 
Cause: An error occurred in the device. 
Corrective action: Confirm the error message, and take action according to the description of the error. 
The keyboard and mouse do not work. 
Cause: The cables are not correctly connected to the USB ports of the Home SB. 
Corrective action: Connect the cables correctly to the USB ports of the Home SB. 
[Part Number] or [Serial Number] in the MMB Web-UI displays [Read Error]. 
Cause: A failure occurred and prevents the part or serial numbers from being read. 
Corrective action: Contact your sales representative or a field engineer. Do not execute [Reset] or [Force 
Power Off] on the partition until the problem is solved. Before making contact, confirm the model name 
and serial number shown on the label affixed to the main unit. 
10.2.8 MMB-related problems 
This section describes MMB-related problems and how to correct the problems. 
No connection to the PRIMEQUEST 2000 series server can be established using the 
Web-UI. 
Cause 1: The setting of the IP address, subnet mask, or gateway is wrong. 
Corrective action: Referring to 3.3.3 Setting up the connection environment for actual operation in the 
PRIMEQUEST 2000 Series Installation Manual (C122-E174EN), set the correct value. 
Cause 2: A failure occurred in the network between the MMB console PC and the MMB USER port. 
Corrective action: Replace the faulty network device or LAN cable. 
Cause 3: A problem occurred in the internal network (e.g., internal hub) of the MMB. 
Corrective action: Switch the active MMB by using the following procedure: 
1.  Log in to the standby MMB via telnet/ssh. 
2.  Execute the set active_mmb command to switch the active MMB. For details on the set active_mmb 
command, see 2.2.12 set active_mmb in the PRIMEQUEST 2000 Series Tool Reference (C122-
E110EN). 
The MMB windows do not appear. 
Cause 1: The MMB LAN port is not enabled. 
Corrective action: Enable the LAN port. 
Cause 2: The MMB console PC is not correctly connected to the MMB USER port. 
Corrective action: Connect them correctly. 
Cause 3: The browser version is not supported. 
Corrective action: The MMB supports the following browsers: 
-  Microsoft Internet Explorer version 8 or later 
-  Mozilla FireFox version 20 or later 
Cause 4: JavaScript is not enabled in the browser. 
Corrective action: The MMB Web-UI uses JavaScript. Enable JavaScript in the browser.