Nortel Networks 555-4001-135 사용자 설명서
Engineering guidelines 37
Nortel Integrated Conference Bridge Service Implementation Guide
System capacity
Physical Capacity
Each ICB card occupies one slot on the Gateway/IPE chassis shelf.
The total number of ICB cards per system is limited by these factors:
The total number of ICB cards per system is limited by these factors:
•
For Meridian 1 or CS 1000M: The number of IPE shelves multiplied
by eight. Option 11C and Wall-Mount systems are limited to six
cards.
by eight. Option 11C and Wall-Mount systems are limited to six
cards.
•
For CS 1000: The number of Gateway chassis shelves multiplied by
four cards.
four cards.
•
For CS 2100/Meridian SL-100: Up to eight cards can be supported
per IPE shelf.
per IPE shelf.
System compatibility
Meridian 1 and Option 11
ICB Release 4 is compatible with the following Meridian 1/Option 11
systems:
systems:
•
Option 11C, 11E, 11C Mini
•
Option 21 and 21E
•
Option 51, 51C
•
Option 61, 61C
•
Option 71
Maximum number of
BUI sessions
BUI sessions
Up to 20 simultaneous user sessions on the BUI. Same is true in dual-card
configuration. There can be up to 500 users per card.
configuration. There can be up to 500 users per card.
Maximum number of
TUI sessions
TUI sessions
Only one user can be active in a TUI session. While one TUI user is active,
other users will wait in the ACD queue.
other users will wait in the ACD queue.
PCMCIA card
PCMCIA Type II or III.
System interface
DS-30X, CE-MUX, Card LAN, Ethernet Adapter.
Maintenance
terminal
terminal
Optivity, VT-100 terminal or PC with VT100 emulation.
Power requirements
Power is supplied by the power supply of the shelf/module where the ICB card
is installed. Each ICB card requires a total maximum power of 3.5 watts.
is installed. Each ICB card requires a total maximum power of 3.5 watts.
Real time impact
Comparable to that of a digital line card (DLC).
Table 2
Hardware specifications (Continued)
Item
Descriptions