Lucent Technologies 555-233-115 사용자 설명서

다운로드
페이지 502
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  
555-233-115  
Issue 1
April 2000
Multicarrier G2 Universal Module to R8r EPN 
5-80
Critical Reliability 
5
14. Slide the carrier forward 1 to 2 inches; then, from the back, be sure that no 
cables or wiring harnesses are caught on the cabinet/carrier framework.
!
CAUTION:
Cables and wiring harnesses can be damaged if they catch on the 
framework and if too much pressure is applied in removing the 
carrier.
15. Remove the carrier by sliding it out the front of the cabinet.
16. Repeat Steps 12 through 15 for the “A” carrier.
17. On port carrier J58890BB-1, connect the TDM cable or the TDM 
terminator to Slot 02. On port carriers J58890BB-2 and J58890BB-3, 
connect the TDM cables or the TDM terminator to Slot 01. If the port 
carrier has J58890BB-1 
and J58890BB-2 printed on it, treat it as a 
J58890BB-1.