DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
Upgrades and Additions for R8r
555-233-115
Issue 1
April 2000
Upgrading R5r/R6r/R7r to R8r without Adding Memory
2-9
Upgrade the software and hardware
2
Disable TTI
NOTE:
Do this step only if the Terminal Translation Initialization (TTI) is enabled.
!
CAUTION:
If you do not disable the TTI, the translations can be corrupted.
1. Type change system-parameters features and press
Enter.
2. On the second screen, set the
TTI Enabled?
field to n to de-activate the
TTI feature.
Check TTI Status
1. Type status tti and press
Enter
. Wait until the
Percent Complete
field
shows 100%.
Busyout MMI Circuit Packs (H/C only)
!
CAUTION:
Multimedia-to-voice station calls are not preserved on an upgrade. Failure
to busy-out the TN787 Multimedia Interface (MMI) circuit packs results in
unusable TN787 and TN788 Multimedia Voice Conditioner ports.
to busy-out the TN787 Multimedia Interface (MMI) circuit packs results in
unusable TN787 and TN788 Multimedia Voice Conditioner ports.
1. Type display system-parameters customer-options and press
Enter
. On
screen 2 under the Multimedia Call Handling (MMCH) options, check the
Basic
and
Enhanced
fields.
2. If either the
Basic
or
Enhanced
field is y, type list configuration all and
press
Enter
to locate all MMI (TN787) circuit packs.
3. If there are MMI circuit packs, type busyout board
cabinet carrier slot
and press
Enter
to remove the circuit packs from service.