Polycom RSS 2000 사용자 설명서

다운로드
페이지 82
Polycom RSS 2000 User’s Guide 
 
 
37
Notes: 
1. 
The archive backup stops immediately when a archive recording/playback starts. 
2. 
If such archive recording/playback ends within the backup period, the archive 
backup will continue. If it ends at or after the backup stop time, the archive backup 
will not continue. Instead, the backup will reset from the very beginning at the same 
start time on the following day and overwrite the partially backed up archive, if 
there is no archive recording/playback in process. 
3. Files 
with 
backups 
are 
distinguished from those without backups by being 
displayed in pink on the webpage. 
You have two choices for the delete policy: never, and after X days. If you choose never cleanup, your archives 
will be stored on the RSS 2000 hard disk forever. If you choose cleanup in certain days after recording, you may 
set a number of days after the recording ends, and the file will be deleted in this number of days, as shown in Fig. 
4-19. 
 
Fig. 4-19 Set Cleanup of files 
You can input a number of days within the range of 0-100, where 0 means that the file will be deleted right on the 
day when the archive recording ends. The time period can be any period within the range of 0:00-23:00, with the 
cleanup stop time after the cleanup start time. 
Note:   
If you have set a 'never delete' property for the recorded archive, the archive can 
never be deleted even if you choose cleanup in the Backup/Cleanup policy.