6
6.2 RS-232 PROTOCOL
The RS-232 protocol for the MT100-102 uses a
simple  ASCII  character  format.  See  the
MT101-110  and  MT101-111  Front  Panel  User
Guides  for  Multi-Tasker™  commands  and
formats.
6.3 USB CONNECTION
Up  to  10  MT100-102's  may  be  connected
together  using  the  USB  LOOP  OUT  and  USB
LOOP  IN  connections  on  the  back  of  the
MT100-102.  Connect  one  MT100-102  to  the
control system or computer. Then, connect the
LOOP OUT connector of that unit to the LOOP
IN  connector  of  the  next  unit.  Use  the  LOOP
OUT and LOOP IN connectors in this manner to
connect the remaining units.
CAUTION: Do not connect the LOOP OUT or
LOOP IN connectors to the USB
PORT as damage may occur to
the input card.
TROUBLESHOOTING GUIDE
7
We  have  carefully  tested  and  have  found  no
problems in the supplied MT100-102; however, we
would like to offer suggestions for the following:
7.1  CARD CAGE IS NOT WORKING
Cause 1: Card cage is not plugged in.
Solution:
Plug  the  card  cage  in.  If  the  card
cage  works,  the  problem  is  solved.
If  the  card  still  does  not  work,  see
Cause 2.
Cause 2: The  input  power  voltage  is
incorrect.
Solution:
Make  sure  that  the  input  power
range is within 85-264VAC and also
make  sure  that  the  power  is
connected  to  the  input  power
connector. If there is still a problem,
call ALTINEX at (714) 990-2300.
7.2  CARD IS NOT WORKING
Cause 1: Card cage slot has a problem.
Solution 1:
Test a card in other slots of the card
cage.  If  the  slot  was  damaged,  the
card may work in other slots. If other
slots  work,  the  problem  is  the  card
cage  slot.  The  card  cage  may
require  service.  Call  ALTINEX  at
(714) 990-2300. If the other slots do
not work, see Solution 2.
Solution 2:
Take  any  other  known  good  card
with an LED and verify that the slot
used is good by seeing if  the  other
card’s  LED  lights  in  that  slot.  If  it
lights, then the original card may be
the  source  of  the  problem.  Call
ALTINEX  at  (714)  990-2300.  If  the
original  card  was  not  the  source  of
the problem, see Cause 2.
Cause 2: Card is not plugged in all the way.
Solution 1:
Push  the  card  in  all  the  way.  If  the
card  still  does  not  work,  see
Solution 2.
Solution 2: See  the  troubleshooting  section  of
each  the  card's  user  guide  or  call
ALTINEX at (714) 990-2300.
ALTINEX POLICY
8
8.1  LIMITED WARRANTY/RETURN POLICY
Please 
see 
the 
Altinex 
website 
at
www.altinex.com
  for  details  on  warranty  and
return policy.
8.2  CONTACT INFORMATION
ALTINEX, INC
592 Apollo Street
Brea, CA  92821 USA
TEL: 714 990-2300
TOLL FREE: 1-800-ALTINEX
WEB: 
www.altinex.com
E-MAIL: 
solutions@altinex.com