Citrix Systems 5.6 사용자 설명서

다운로드
페이지 235
79
Configuring a dedicated storage NIC
XenServer allows use of either XenCenter or the xe CLI to configure and dedicate a NIC to specific functions,
such as storage traffic.
Assigning  a  NIC  to  a  specific  function  will  prevent  the  use  of  the  NIC  for  other  functions  such  as  host
management, but requires that the appropriate network configuration be in place in order to ensure the NIC
is used for the desired traffic. For example, to dedicate a NIC to storage traffic the NIC, storage target,
switch, and/or VLAN must be configured such that the target is only accessible over the assigned NIC. This
allows use of standard IP routing to control how traffic is routed between multiple NICs within a XenServer.
Note:
Before dedicating a network interface as a storage interface for use with iSCSI or NFS SRs, ensure that the
dedicated interface uses a separate IP subnet which is not routable from the main management interface. If
this is not enforced, then storage traffic may be directed over the main management interface after a host
reboot, due to the order in which network interfaces are initialized.
To assign NIC functions using the xe CLI
1. Ensure that the PIF is on a separate subnet, or routing is configured to suit your network topology in
order to force the desired traffic over the selected PIF.
2. Setup an IP configuration for the PIF, adding appropriate values for the mode parameter and if using
static IP addressing the IP, netmask, gateway, and DNS parameters:
xe pif-reconfigure-ip mode=
<DHCP | Static>
 uuid=
<pif-uuid>
3. Set the PIF's disallow-unplug parameter to true:
xe pif-param-set disallow-unplug=true uuid=
<pif-uuid>
xe pif-param-set other-config:management_purpose="Storage" uuid=
<pif-uuid>
If you want to use a storage interface that can be routed from the management interface also (bearing in
mind that this configuration is not recommended), then you have two options:
• After a host reboot, ensure that the storage interface is correctly configured, and use the 
xe pbd-unplug
and 
xe pbd-plug commands to reinitialize the storage connections on the host. This will restart the storage
connection and route it over the correct interface.
• Alternatively,  you  can  use 
xe  pif-forget  to  remove  the  interface  from  the  XenServer  database,  and
manually configure it in the control domain. This is an advanced option and requires you to be familiar
with how to manually configure Linux networking.
Controlling Quality of Service (QoS)
Citrix XenServer allows an optional Quality of Service (QoS) value to be set on VM virtual network interfaces
(VIFs) using the CLI. The supported QoS algorithm type is rate limiting, specified as a maximum transfer
rate for the VIF in Kb per second.
For example, to limit a VIF to a maximum transfer rate of 100kb/s, use the 
vif-param-set command:
xe vif-param-set uuid=
<vif_uuid>
 qos_algorithm_type=ratelimit
xe vif-param-set uuid=
<vif_uuid>
 qos_algorithm_params:kbps=100
Changing networking configuration options
This section discusses how to change the networking configuration of a XenServer host. This includes: