Compatible Systems Enterprise-8 사용자 설명서
Chapter 8 - LED Patterns and Test Switch Settings
31
IntraPort Enterprise-8 Switch Settings
The switch for Ethernet 0:0 controls the entire device. For example, if you set the switch for
Ethernet 0:0 to “3” and download new software to the device, the other interfaces will auto-
matically receive the software update from Ethernet 0:0 via the backplane. In general, the only
time you should use an individual RIOP card’s switch is when the card is unable to communi-
cate with the backplane for some reason.
Ethernet 0:0 to “3” and download new software to the device, the other interfaces will auto-
matically receive the software update from Ethernet 0:0 via the backplane. In general, the only
time you should use an individual RIOP card’s switch is when the card is unable to communi-
cate with the backplane for some reason.
M Caution: Settings marked with an asterisk may erase your Flash ROM. Please do not use
these settings without first contacting Compatible Systems’ Technical Support.
these settings without first contacting Compatible Systems’ Technical Support.
0
Normal Operation
1
Unused*
2
Unused*
3
Run Boot ROM Downloader
4
Unused*
5
Erase Flash ROM (OS and Configuration)
6
Erase Flash ROM (Configuration Only)
7
Unused*
8
Unused*
9
Allow letmein password for 5 minutes after powerup