Fujitsu P3PC-1132-07ENZ0 사용자 설명서
48
■ [Advance] Tab
When receiving image data, the trigger port number for the fi-5000N, may conflict with other
applications.
This setting is used to change the trigger port number on the PC.
applications.
This setting is used to change the trigger port number on the PC.
■ [Version] Tab
This tab shows the version information of the fi-5000N Configuration Tool.
Name of Item
Function
Trigger port (PC):
Used to specify a trigger port number on the PC.
[Default] button:
Resets to the default number.
ATTENTION
When changing the trigger port number on the PC, you must also change
the trigger port on the fi-5000N. Refer to "5.5 fi-5000N Administrator Set-
tings" (page 57). If the both port numbers are not the same, the fi-5000N
will not work correctly.
the trigger port on the fi-5000N. Refer to "5.5 fi-5000N Administrator Set-
tings" (page 57). If the both port numbers are not the same, the fi-5000N
will not work correctly.