Possible cause
The document was moved
during the read operation.
The document was not in
contact with the glass.
The carrier fixing bracket
was not removed.
——————————
The pick roller is dirty.
The unallowable document
was read in the automatic
document feeder.
(See Section 4.3.)
Pad is dirty.
Pad is worn out.
Pick roller is dirty.
Pick roller is worn out.
Some foreign particles are in
ADF.
Problem
Image is dis-
torted or un-
clear.
The check
indicator is on.
“Check” lamp
blinks at 4
seconds period.
Paper double feed.
Miss pick.
Paper jam.
Response
Keep the document cover closed during
reading so that the document will not be
moved.
Adjust the document so that it is in
contact with the glass.
Remove the carrier fixing bracket as
explained in Section 3.2, “Removing the
Carrier Fixing Bracket.”
Turn the power off then on again.  If the
check indicator turns on again, contact the
sales person in charge or a Fujitsu service
representative.*
When the power is turned off, the mes-
sage is cleared.
Even if the message is displayed, the read
operation can be continued. Clean the
pick roller after the read operation.
(See Section 5.3.2.)
If a document not meeting the scanner
specifications is read in the automatic
document feeder, the document is not fed
smoothly and an error message may be
displayed.
Read the document in the flat bed station.
Clean the Pad. (See Section 5.3.2)
Replace the Pad. (See Section 5.4.2)
Clean the Pick roller. (See Section 5.3.2)
Replace the Pick roller.
(See Section 5.4.3)
Clean the ADF (See Section 5.3.2) or
remove any foreign particles.
Table 6.1
Check items (continued)
* Please check the test mode in appendix B, if possible, before calling the service representa-
tive and inform status of the indicators.