Motorola MS4404 사용자 설명서
Symbol MS4404 - RS-232 (Serial) Interface
9 - 3
Serial Host Parameters
Various serial hosts are set up with their own parameter default settings (
). Selecting standard, ICL,
Fujitsu, Wincor-Nixdorf Mode A, Wincor-Nixdorf Mode B, OPOS/JPOS, Olivetti, or Omron sets the defaults listed
below.
below.
Selecting ICL, Fujitsu, Wincor-Nixdorf Mode A, Wincor-Nixdorf Mode B, OPOS/JPOS, Olivetti, or Omron enables
the transmission of code ID characters listed in
the transmission of code ID characters listed in
. These code ID characters are not programmable and
are separate from the Transmit Code ID feature. Do not enable the Transmit Code ID feature for these terminals.
Table 9-2
Terminal Specific Serial
Parameter
ICL
Fujitsu
Wincor-Nixdorf
Mode A
Wincor-Nixdorf
Mode
B/OPOS/JPOS
Olivetti
Omron
Transmit Code ID
Yes
Yes
Yes
Yes
Yes
Yes
Data Transmission
Format
Format
Data/Suffix
Data/Suffix
Data/Suffix
Data/Suffix
Prefix/Data/
Suffix
Suffix
Data/Suffix
Suffix
CR (1013)
CR (1013)
CR (1013)
CR (1013)
ETX (1002)
CR (1013)
Baud Rate
9600
9600
9600
9600
9600
9600
Parity
Even
None
Odd
Odd
Even
None
Hardware
Handshaking
Handshaking
RTS/CTS
Option 3
Option 3
None
RTS/CTS
Option 3
Option 3
RTS/CTS Option
3
3
None
None
Software Handshaking
None
None
None
None
Ack/Nak
None
Serial Response
Time-out
Time-out
9.9 Sec.
2 Sec.
9.9 Sec.
9.9 Sec.
9.9 Sec.
9.9 Sec.
Stop Bit Select
One
One
One
One
One
One
ASCII Format
8-Bit
8-Bit
8-Bit
8-Bit
7-Bit
8-Bit
Beep On <BEL>
Disable
Disable
Disable
Disable
Disable
Disable
RTS Line State
High
Low
Low
Low = No data to
send
send
Low
High
Prefix
None
None
None
None
STX (1003)
None
*In the Nixdorf Mode B, if CTS is Low, imaging is disabled. When CTS is High, you can capture bar codes.
**If you select Nixdorf Mode B and the imager is not connected to the proper host, it may appear unable to
decode. If this happens, select a different serial host type within 5 seconds of cycling power to the imager.
**If you select Nixdorf Mode B and the imager is not connected to the proper host, it may appear unable to
decode. If this happens, select a different serial host type within 5 seconds of cycling power to the imager.