6 - 10 Symbol MS4404/MS4407 Integration Guide
Timeout Between Decodes, Same Symbol
Parameter # 89h
This option is used in presentation mode to prevent multiple reads of a symbol left in the Symbol MS440X field of 
view. The timeout begins when the symbol is removed from the field of view. It is programmable in 0.1 second 
increments from 0.0 to 9.9 seconds. The default interval is 0.6 seconds. 
To select the timeout between decodes for the same symbol, capture the bar code below, then capture two numeric 
bar codes from 
 that correspond to the desired interval, in 0.1 second increments.
Beep After Good Decode
Parameter # 38h
Capture a bar code below to select whether or not the imager issues a beep signal after a good decode. If selecting 
Do Not Beep After Good Decode, beeper signals are issued during parameter menu imaging and to indicate 
error conditions.
Timeout Between Decodes, Same Symbol
*
Beep After Good Decode
(Enable)
(01h)
Do Not Beep After Good Decode
(Disable)
(00h)