Scanner Options
 
 
Step 2 
Patchcode-Based 
Actions 
If the field width is equal to a value of anything but 0, the Counters A, B, C, 
and D will be reset and then incremented by the specified values. For details, 
see Chapter 
Then, the flags, the level, or the mode will be changed. 
When the rule changes, the Counter A or the level will be denoted. 
If the No Count action is wanted, this will be denoted as well. 
In addition, all the hardware related actions such as Drop PageStop 
Scanner
, and Endorser On/Off will not take effect immediately. They will be 
retained until Step 7. 
 
Step 3 
Level-Based Events 
Now the current level will be checked. 
This check will be done only if the level was not changed by a Patchcode-
based rule before, as seen in Step 2 above. Otherwise, the procedure goes on 
with Step 5, which is the incrementing of the automatic counters. 
Only one level can be active at a time, so only one of the four levels can cause 
resulting actions. 
When a level-based rule becomes true the resulting action will be done: 
 
Step 4 
Level-Based Actions 
This is the same as Step 2. 
 
Step 5 
Increment the 
Automatic Counters 
If the No Count option was enabled in Step 2 or Step 4, this step will be 
skipped. 
If not, the Sequential ID will now be incremented by 1. 
If Counter A was not changed before, it will be incremented by 1 as well. 
It doesn’t make sense to enable the No Count option after this step (i.e. in 
the "Counter-based” rules). 
 
Step 6 
Counter-Based 
Events und Actions 
The counters will now be checked to reach their trigger values. They will be 
checked in the order A, B, C, and then D. 
After each check the resulting actions (except the hardware actions, as seen in 
Steps 2 and 4) will be performed immediately.  
 
Page 36 of 42