U-Line CLR2160 사용자 설명서

다운로드
페이지 28
CLR2160CLRCO2175
25
Unit runs but produces very little ice.
Dirty condenser coils
Clean the condenser (See MAINTENANCE; CONDENSER 
CLEANING).
High air temperature around unit
Surrounding air temperature of over 90°F. Low ice 
production at high temperatures is normal.
Scale and mineral buildup in unit
Run unit through self cleaning cycle (See 
MAINTENANCE; ICE MAKER: SELF CLEANING CYCLE.
Inadequate airflow at the front of 
the unit
Remove items blocking airflow.
Cleaning Cycle recently performed
Allow unit to reach the set temperature to produce ice 
normally.
Poor ice quality (soft or unclear)
Unit is not level.
Level unit (See MAINTENANCE; LEVELING).
Poor incoming water quality
Consult a qualified plumber to test the water quality 
and recommend appropriate treatment.
Ice-making system is dirty.
Run unit through self cleaning cycle (See 
MAINTENANCE; ICE MAKER: SELF CLEANING CYCLE).
Unit produces shallow or incomplete 
cubes, or the ice fill pattern on the 
evaporator is incomplete.
Low water level
Check to see that overflow tube is fully seated.
Hot incoming water
Connect the unit to a cold water supply.
Incorrect incoming water pressure
Water pressure must be 20-120 psi.
Unit is not level.
Level unit (See MAINTENANCE; LEVELING).
Ice is slow to release or does not 
release from the evaporator.
Ice-making system is dirty.
Run unit through self cleaning cycle (See 
MAINTENANCE; ICE MAKER: SELF CLEANING CYCLE).
Unit is not level.
Level the unit (See MAINTENANCE: LEVELING).
Low air temperature around unit
Surrounding air temperature must be at least 50°F.
Ice storage bin full of water
Obstructed drain
Check to see that storage bin drain opening is free from 
obstruction and debris.
Water leaking from under the unit
Supply line leaking
Tighten connection as required.
Fill tube leaking
Check connection at water valve outlet.
Bin drain leaking
Check integrity of bin drain hose and clamp.
PROBLEM
POSSIBLE CAUSE
REMEDY