DELL MD3220 사용자 설명서

다운로드
페이지 260
Management: Installing Array Components
197
Installing a Hard Drive Into a Drive Carrier
Insert the hard drive into the hard-drive carrier with the connector end 
of the drive at the back. See Figure 15-5.
Align the screw holes on the hard drive with the back set of holes on the 
hard-drive carrier. 
When aligned correctly, the back of the hard drive is flush with the back of 
the hard-drive carrier.
Attach the four screws to secure the hard drive to the hard-drive carrier.
RAID Controller Module 
An MD3200 series storage array supports single as well as dual RAID 
controller configurations. If only one RAID controller module is installed in 
your array, it must be installed in slot 0. You must install the RAID controller 
module blank in slot 1.
 
CAUTION: 
RAID controller modules can be removed and installed without turning 
off the array. It is recommended that you do not remove the RAID controller module 
while data is being transferred. Replacing or installing a RAID controller module 
that is connected to a host server causes it to loose communication with the array 
and may require a reboot of the host server.
Removing a RAID Controller Module Blank
 
CAUTION: 
To maintain proper system cooling, you must install a RAID controller 
module blank in the empty slot.
Turn off the array and host server.
Disconnect all the power cables connected to the array.
To remove the RAID controller module blank, press down on the release 
latch and pull the blank away from the array. See Figure 15-7.
Install RAID controller modules in slot 0 and 1. See "Installing a RAID 
book.book  Page 197  Monday, June 21, 2010  11:00 AM