Management: Installing Array Components
Installing the Backplane
Align the holes on the backplane with the holes on the array.
Tighten the captive screw to secure the backplane to the chassis. 
See Figure 15-16 for PowerVault MD3200 or Figure 15-17 for 
PowerVault MD3220.
Replace the screws that secure the backplane to the chassis. 
See Figure 15-16 for PowerVault MD3200 or Figure 15-17 for 
PowerVault MD3220.
Align the slots on the RAID controller module /power supply cage with the 
tabs on the chassis. See Figure 15-15.
Push the RAID controller module /power supply cage toward the front of 
the array.
Replace the screws that secure the RAID controller module /power supply 
cage to the chassis.
Replace the control panel. See "Installing the Control Panel" on page 208.
Replace the power supply/cooling fan modules. See "Installing a Power 
10 Connect all the cables to the array.
11 Turn on the array and the host server.