Troubleshooting: Your Array
247
Troubleshooting Array and Expansion Enclosure 
Connections
Verify that the RAID controller module port link status LED and the 
RAID controller module status LED are solid green for each port that is 
connected to a cable. If the LEDs are not solid green, see "Planning: RAID 
Ensure that all the cables are attached correctly according to array mode 
you selected.
Turn off the server, storage array, and expansion enclosures. 
Reseat the RAID controller module and reconnect cables on the storage 
array and the server.
Turn on the expansion arrays and then the storage array and wait until the 
system is fully booted.
Turn on the server.
Check the link status LED. If the link status LED is not green, replace the 
cables.
If the problem is not resolved, see "Getting Help" on page 253.
Reboot the host server.
 
NOTE: 
You must turn off the host server before resetting the cables on 
the storage array or expansion enclosure.
If the problem is not resolved, see "Getting Help" on page 253.