Planning: About Your Storage Array
27
Power Supply and Cooling Fan Features
The MD3200 Series storage array includes two integrated, hot-swappable 
power supply/cooling fan modules. Both modules must be installed to ensure 
proper cooling. Each module contains two separate cooling fans. The system 
requires at least one of the cooling fans to function to avoid overheating. 
A power supply/cooling fan module can be replaced without powering down 
the system. For information on removing and replacing the modules, see 
 
CAUTION: 
A power supply/cooling fan module can be removed from a powered-
on enclosure for a maximum period of 5 minutes. Beyond that time, the system may 
automatically shut down to prevent damage.
Drive-Status Indicator Pattern
Condition
Off
The physical disk is:
• not yet discovered by the host server
• has been spun down for removal 
• not supported for the RAID controller 
module or is not in the physical disk slot
NOTE: 
The drive status indicator remains 
off until all hard drives are initialized 
after system power is turned on. 
Drives are not ready for insertion or 
removal during this time.
Steady green
Physical disk is online
Green flashing (On 250 ms, Off 250 ms) Physical disk is being identified
Green flashing (On 400 ms, Off 100 ms) Physical disk rebuilding
Amber flashing (On 150 ms, Off 150 ms) Physical disk failed
Flashing green, amber, and off (Green On 
500 ms, Amber On 500 ms, Off 1000 ms)
Physical disk failure predicted (SMART)
Flashing green, amber, and off (Green 3 
seconds, amber 3 seconds, and off 3 
seconds)
Physical disk rebuild aborted
book.book  Page 27  Monday, June 21, 2010  11:00 AM