DELL MD3220 사용자 설명서

다운로드
페이지 260
Planning: MD3200 Series Storage Array Terms and Concepts
37
If a disk drive rebuild fails because of a source drive failure or because the 
drive is too small, the MDSM reports a failure of the physical disk even 
though the LED state on the drive indicates the rebuild was aborted (green 
for 3 seconds, amber for 3 seconds, then off for 3 seconds).
Self-Monitoring Analysis and Reporting Technology
SMART monitors the internal performance of all physical disk components to 
detect faults indicating the potential for physical disk failure. SMART uses 
this information to report whether failure is imminent so that a physical disk 
can be replaced before failure occurs. The storage array monitors all attached 
drives and notifies you when a predicted failure is reported by a physical disk. 
Virtual Disks and Disk Groups
When configuring a storage array, you must:
Organize the physical disks into disk groups. 
Create virtual disks within these disk groups. 
Pending 
Failure
Assigned, 
Unassigned, 
Hot Spare in 
use, or Hot 
Spare standby
A Self-Monitoring Analysis and 
Reporting Technology (SMART) error 
has been detected on the physical disk 
in the indicated slot.
Flashing Green 
(500 ms), Amber 
(500 ms), and off 
(1000ms)
Offline
Not applicable The physical disk has either been spun 
down or had a rebuild aborted by user 
request.
Flashing Green 
(3000 ms), Amber 
(3000 ms), and 
off(3000ms)
Identify
Assigned, 
Unassigned, 
Hot Spare in 
use, or Hot 
Spare standby
The physical disk is being identified. Green flashing 
(250 ms)
N/A
N/A
The indicated slot is empty, or the 
array cannot detect the physical disk.
Table 4-1. RAID Controller Physical Disk States  
(continued)
Status
Mode
Description
Physical Disk 
Status LED
book.book  Page 37  Monday, June 21, 2010  11:00 AM