DELL MD3220 사용자 설명서

다운로드
페이지 260
Configuration: About Your Storage Array
63
6
Configuration: About Your Storage 
Array
Out-of-Band and In-Band Management
You can manage a storage array in two ways:
• Out-of-band management 
• In-band management 
Out-of-Band Management
Using the out-of-band management method, data is separate from 
commands and events. Data travels through the host-to-controller interface, 
while commands and events travel through the management port Ethernet 
cables. 
This management method lets you configure the maximum number of 
virtual disks that are supported by your operating system and host adapters. A 
maximum of eight storage management stations can concurrently monitor an 
out-of-band managed storage array. This limit does not apply to systems that 
manage the storage array through the in-band management method.
When you use out-of-band management, you must set the network 
configuration for each RAID controller module’s management Ethernet port. 
This includes the Internet Protocol (IP) address, subnetwork mask (subnet 
mask), and gateway. If you are using a Dynamic Host Configuration Protocol 
(DHCP) server, you can enable automatic network configuration, but if you 
are not using a DHCP server, you must enter the network configuration 
manually.
 
NOTE: 
RAID controller module network configurations can be assigned using a 
DHCP server (the default setting). However, if a DHCP server is not available for 150 
seconds, the RAID controller modules assign static IP addresses. The addresses 
assigned are 192.168.128.101 for controller 0 and 192.168.128.102 for controller 1. 
book.book  Page 63  Monday, June 21, 2010  11:00 AM