Configuration: About Your Host
If the host context agent is running, click Action Stop, then wait 
approximately 5 seconds. 
Click Action Start
I/O Data Path Protection
You can have multiple host-to-array connections for a host. Ensure that you 
select all the connections to the array when configuring host access to the 
storage array.
 
NOTE: 
See the Deployment Guide for more information on cabling configurations.
 
NOTE: 
For maximum redundancy, you must select all host connections to the array 
when manually defining host topology. For example, a host might have two host 
connections listed when manually configuring host access. For this host, you would 
select the two host connections listed in the Available hosts section and add them 
to the Selected hosts section using the Add button.
 
NOTE: 
For more information on configuring hosts see "Configuration: About Your 
If a component such as a RAID controller module or a cable fails, or an error 
occurs on the data path to the preferred RAID controller module, virtual disk 
ownership is moved to the alternate non preferred RAID controller module 
for processing. This feature is called failover.
Drivers for multi-path frameworks such as Microsoft Multi-Path IO (MPIO) 
and Linux Device Mapper (DM) are installed on host systems that access the 
storage array and provide I/O path failover.
For more information on Linux DM please see "Configuration: Device 
Mapper Multipath for Linux" on page 167. For more information on MPIO 
please see microsoft.com.
 
NOTE: 
You should have the multi-path driver installed on the hosts at all times, 
even in a configuration where there is only one path to the storage system, such as 
a single port cluster configuration.
During a failover, the virtual disk transfer is logged as a critical event, and an 
alert notification is sent automatically if you have configured alert 
destinations for the storage array.
book.book  Page 90  Monday, June 21, 2010  11:00 AM