c)  Electrical Connections – Voltage Output Units 
 
The cable assembly should be connected to the sensor as detailed in 
section 5(b) above. Do not apply power to the sensor until all the 
connections have been made and checked. Electrical connections should 
be made as follows: 
 
 
Wiring Schematic For Voltage Output Units. 
 
 
 
The RED wire should be connected to the Positive of the power source.  
 
The BLACK wire should be connected to the Negative ( Ground ) of the 
power source. 
 
The WHITE wire provides the signal output and should be connected to 
the positive terminal of the display, data acquisition system or voltmeter 
with an impedance greater than 2500Ω (Ohms).  
 
The GREEN wire is not used. 
 
 
 
Caution: Avoid high voltage static discharges to any of the 
connections. Do not short the input/output signal wires or allow 
them to contact the power wires at any time. DAMAGE WILL 
RESULT!