Tandberg Data SCSI DLT-V4 Internal Black 7301708700 사용자 설명서

제품 코드
7301708700
다운로드
페이지 81
Chapter 4  Using Your Tape Drive
Diagnostic Mode Event Codes
DLT-V4 Product Manual
52
Diagnostic Mode Event Codes
4
Press, hold, and release the unload button after six to nine seconds to start 
the diagnostic mode. This displays the most recent event code. The 
unload button then becomes a scroll button for additional event codes. 
Press and release the unload button for the next most recent event code. 
You can display up to five total events using this method. See 
 for 
details about the meaning of the various patterns.
After you display the final available event code, the next button press 
causes all LEDs to flash indicating that the next eight hex characters 
displayed are the detailed error code of the most recent event. The first 
Read/write 
diagnostic start
Caution:
This feature overwrites any data 
currently on the data cartridge. Before 
performing this action, confirm that the 
data cartridge in the tape drive does not 
contain critical data.
Release the unload button to start an internal read/
write diagnostic. You must then load a data 
cartridge to run the diagnostic. The tape drive 
writes and reads 3.6 GB of data, then unloads the 
data cartridge. This process takes approximately 13 
minutes. When completed, the green LED remains 
steadily on. At this point, push the 
Eject
 button to 
eject the cartridge.
The tape drive returns to normal operation if it 
detects no errors. The appropriate LEDs illuminate 
if an error occurs.
Emergency reset
Release the unload button to force an internal reset. 
The tape drive initializes as if you turned power off 
and then on (POST).
Revert back to 
normal mode
Release the unload button to return the tape drive 
to normal operation.
Field/Mode
Actions