Appendix C: POST Error Beep Codes 
Revision – 1.00 
 
 
Intel order number D31980-004 
101
Appendix C: POST Error Beep Codes 
The following table lists POST error beep codes. Prior to system Video initialization, BIOS uses 
these beep codes to inform users on error conditions. The beep code is followed by a user 
visible code on POST Progress LEDs. 
Table 58. POST Error Beep Codes 
Beeps 
Error Message 
POST Progress Code 
Description 
Memory error 
 
System halted because a fatal error related to the memory 
was detected. 
BIOS rolling back 
error 
 
The system has detected a corrupted BIOS in the flash 
part, and is rolling back to the last good BIOS. 
 
The BMC may generate beep codes upon detection of failure conditions. Beep codes are 
sounded each time the problem is discovered, such as on each power-up attempt, but are not 
sounded continuously. Codes that are common across all Intel
®
 server boards and systems that 
use the Intel
®
 5000 Series Chipsets are listed in Table 59. Each digit in the code is represented 
by a sequence of beeps whose count is equal to the digit.  
Table 59. BMC Beep Codes 
Code 
Reason for Beep 
Associated Sensors 
Supported? 
1-5-2-1 
CPU: Empty slot / population error – Processor 
slot 1 is not populated.  
CPU Population Error 
Yes 
1-5-2-2 
CPU: No processors (terminators only) 
N/A 
No 
1-5-2-3 
CPU: Configuration error (e.g., VID mismatch) 
N/A 
No 
1-5-2-4 
CPU: Configuration error (e.g., BSEL mismatch)  N/A 
No 
1-5-4-2 
Power fault: DC power unexpectedly lost (power 
good dropout) 
Power Unit – power unit 
failure offset 
Yes 
1-5-4-3 
Chipset control failure 
N/A 
No 
1-5-4-4 
Power control fault 
Power Unit – soft power 
control failure offset 
Yes