Intel SERVER CHASSIS SR2500 SR2500 사용자 설명서

제품 코드
SR2500
다운로드
페이지 115
Intel® Server System SR2500AL Cooling 
Subsystem 
Revision – 1.00 
 
 
Intel order number D31980-004 
23
 
Table 15.  Nonredundant Fan Header Assignment 
Fan ID 
Mid-plane Fan Header Name 
Fan #1  -  CPU1 cooling 
FAN_2 
Fan #2  -  CPU2 cooling 
FAN_4 
Fan #3  -  PCI Cooling 
FAN_6 
 
3.2  Redundant System Fan Module   
TP02102
 
Figure 17. Fan Module Assembly 
 
Table 16  Redundant Cooling Zones 
 
 
 
 
 
Each 10-pin fan connector provides power and ground, PWM control, tachometer output, a fan 
present detection signal, and a fault LED signal allowing it to be monitored independently by 
server management software. The following table provides the pin-out and description for the 
connectors on each fan. 
Fan 
Cooling 
Zone 
Description of greatest cooling influence 
System Fan #1 & #2 
CPU1 
Primary cooling for CPU1 and memory 
System Fan #2 & #3 
CPU2 
Primary cooling for hard drives hard drives 4 and 
5, CPU2, the BNB, and the low profile PCI cards 
System Fan #5 & #6 
PCI 
Primary cooling for hard drives 2 and 3, Full 
Height PCI cards, PXH and IOP80333 chipset 
Power Supply Fans 2 
fans per module 
Power 
Supply 
Primary cooling for  hard drives 0 and 1, and the 
power supply module(s)