Graco 309550Y 사용자 설명서

다운로드
페이지 46
Setup 
12
309550Y
Setup
* (W) Not included with spatter gun.
1.
Close fluid valves A and B.
2.
Connect A (ISO) and B (RESIN) fluid hoses to fluid 
manifold. 
3.
Engage piston safety lock, page 10.
4.
Connect gun air whip hose (V) and air valve (W*) 
to main air hose. Attach fluid manifold (M) to gun. 
TI2411A
A (ISO)
B (RESIN) 
TI2417A
TI2409A
TI2554A
V
M
W*
To change position of fluid manifold or use 
optional fluid inlets, see pages 16 and 17.
5.
Connect quick coupler (D). Turn on air. Open air 
valve (W*). Air should flow from nozzle (N).
To use optional air inlet, see page 17.
6.
Disengage piston safety lock, page 10.
7.
Trigger gun to check for full mix chamber travel. 
Front of air cap (C) should be approximately flush 
with front retaining ring (U).
TI2414-1A
D
N
W*
TI2410A
TI2414-1A
C
U