Graco 309550Y 사용자 설명서
Flat Spray Tips
18
309550Y
Flat Spray Tips
1.
Follow Pressure Relief Procedure, page 15.
2.
Remove air cap (10) and flat spray tip (39). Inspect
o-ring (40).
If tip is stuck, pry off with small screwdriver or pull
off with pliers. Tip is hardened to resist damage.
off with pliers. Tip is hardened to resist damage.
3.
To clean, soak tip in compatible solvent, see page
TI2557A
10
39
40
4.
Reposition tip horizontally or vertically, or install dif-
ferent tip size.
5.
Reinstall air cap hand tight. Cleaning hole align-
ment to tip not important.
TI2649A
TI2648A