Clean Mix Chamber Nozzle
Clean Passages
If necessary, clean out passages in fluid housing and 
handle with drill bits. Refer to T
View on page 26 for diameter and location of passages. 
All drill bits are available in an accessory kit. Order kit 
248969 for Air Purge Handle Drill Kit, see page 40.
Clean Impingement Ports
1.
Engage piston safety lock, page 10.
2.
Refer to T
ABLE
 1. Also see identification chart 
under Drill Bit Kits, page 39. Use the appropriate 
size drill bit to clean mix chamber nozzle (N). If 
necessary, clean air cap (C) gently with stiff brush.
Table 1: Nozzle Drill Bit Sizes
Round Spray
Flat Spray
Mix Chamber
Part No.
Drill Size 
in. (mm)
Mix Chamber
Part No.
Drill Size 
in. (mm)
AR2020
#58, .042
(1.00)
AF2020
3/32, .094
(2.35)
AR2929
#55, .052
(1.30)
AF2929
3/32, .094
(2.35)
AR3737
#55, .052
(1.30)
AR4242
#53, .060
(1.50)
AF4242
3/32, .094
(2.35)
AR5252
#50, .070
(1.75)
AF5252
3/32, .094
(2.35)
AR6060
#44, .086
(2.15)
AR7070
3/32, .094
(2.35)
AR8686
#32, 0.116
(2.90)
TI2409A
N
TI2418A
C
Table 2: Passage Diameters
Passage Description
Ref. Letter 
(page 26)
Diameter,
in. (mm)
Optional Air Inlet
C
7/16, 1/8
(11.0, 3.1)
Purge Air
D
1/8 (3.1)
Piston Air
E, F
1/8 (3.1)
Air Exhaust
G
11/32, 1/8
(8.7, 3.1)
Air Valve Bore
H
9/32 (7.1)
Cleanoff Air
Not Shown
3/32 (2.35)
Check Valve Holes
Not Shown
3/32 (2.35)
Grease
Not Shown
3/32 (2.35)
1.
2.
Disconnect air (D) and remove fluid manifold (M). 
3.
29.
4.
TI2554A
M
D