Graco 309550Y 사용자 설명서

다운로드
페이지 46
Repair
309550Y
31
Check Valves
Before disassembling, press on ball (26c) to test 
check valve for proper movement and spring 
action.
1.
2.
Remove fluid manifold (M). Leave air connected. 
3.
Flush gun to remove residual A and B compo-
4.
Disconnect air.
CAUTION
To prevent cross-contamination of the check valves, 
do not interchange A component and B component 
parts. The A component check valve is marked with 
an A.
TI2543A
M
TI2540A
5.
Pry out check valves (26) at notch.
WARNING
Read warnings, page 7. Damaged check valve o-rings 
(26f, 26g) may result in external leakage. Replace 
o-rings if any damage is seen. 
6.
Slide filter (26d) off. Clean and inspect parts. Thor-
oughly inspect o-rings (26f, 26g). If necessary, 
remove screw (26b) and disassemble entire check 
valve.
7.
Reassemble check valves. Screw (26b) should be 
flush (within 1/16 in. or 1.5 mm) of housing (26a) 
surface. Liberally lubricate o-rings (26f, 26g) and 
carefully reinstall in fluid housing.
8.
Attach fluid manifold. Connect air. Return gun to 
service.
26b
26
B
A
26e
26c
26d
26g
26a
26f
TI2429A