Compressor Module
The compressor is used to reduce or limit transient 
peaks in a signal, while providing make-up gain to 
compensate. As the input level to the compressor 
increases, the output level increases linearly until 
the threshold point is reached. After that point, the 
output level no longer increases linearly, but in-
creases at a reduced rate that is determined by the 
ratio setting.
The compressor also has a soft knee and a limit 
feature, with controls to adjust attack, release, 
threshold, ratio, and gain.
Nodes T, R and G
Threshold, Ratio and Gain can be adjusted by grab-
bing the nodes with your wee mousie.
Ctrl (control)-click to reset the nodes to their 
default positions.
Reduction meter
This meter indicates the amount of gain reduction in dB that is applied to the signal once it crosses 
the threshold.
Input and Output meters
These meters indicates the signal level before and after it enters the compressor. 
Sof t
Attack
Compressor
Release
Limit
Threshold
Ratio
Gain
Reduction
Meter
Input
Meter
Output