U.S. AND FOREIGN PATENTS PENDING 
 
 
READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING LUMINAIRE 
This luminaire is intended for installation in accordance with the National Electrical Code and local regulations.  
To assure full compliance with local codes and regulations, check with your local electrical inspector before 
installation.  To prevent electric shock, turn off electricity at fuse box before proceeding. 
Retain these instructions for maintenance reference. 
INSTRUCTION SHEET NO. 
IS: C3MR 
B0206
 
Page 2 of 2 
 COMPANY
 
631 Airport Road, Fall River, MA 02720
INSTALLATION PROCEDURE FOR CALCULITE
® EVOLUTION TRIMS
8. Install TRIM FACEPLATE by compressing TORSION SPRING 
into corresponding detail of TRIM BODY then pushing TRIM 
FACEPLATE up flush to ceiling. Fig’s 4 & 5 
 
TRIM MAINTENANCE 
RELAMPING - Make sure that power to luminaire is OFF. 
To relamp, simply swing TRIM FACEPLATE down allowing 
TORSION SPRING to hold in place. Pull down on LAMP 
REMOVAL SPRING. Disconnect LAMP from LAMP 
SPRINGS and SOCKET. Install new LAMP following steps 
4, 5, and 6 above. 
 
CARE OF ALZAK REFLECTOR- Wipe with a soft, clean, 
dry, lint-free cloth, or wipe with a soft clean cloth 
dampened in mild detergent solution, then rinse and 
dry with a lint-free soft cloth. 
 