Philips QCE2X4PFOS 전단

다운로드
페이지 2
Alter Concept Elegance
Page 2 of 2 
2' x 4' direct/indirect recessed fluorescent
Job Information 
Type:
Lightolier is a Philips group brand
Lightolier 
www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2008 Philips Group • QCE2x4PFOS.pdf
Canlyte 
www.canlyte.com
3015 Louis-Amos, Lachine, Québec  H8T 1C4 • (514) 636-0670 • (514) 636-0460
 
 
  
ZONE  
 
 
 
 
 
DEG   
 
ALONG  22.5 
45 
67.5 
ACROSS
 
 
 
 
 
 
  0 
1163 
1163 
1163 
1163 
1163
  5 
1156 
1165 
1158 
1157 
1153
10 
1142 
1147 
1150 
1145 
1146
15 
1116 
1120 
1127 
1128 
1132
20 
1077 
1084 
1097 
1100 
1105
25 
1032 
1041 
1054 
1070 
1074
30 
973 
995 
1008 
1027 
1042
35 
910 
925 
952 
983 
998
40 
834 
854 
891 
939 
951
45 
743 
771 
826 
870 
892
50 
643 
676 
750 
805 
833
55 
545 
585 
674 
744 
776
60 
441 
495 
598 
673 
704
65 
344 
407 
514 
573 
589
70 
254 
326 
418 
445 
444
75 
168 
244 
294 
256 
242
80 
100 
152 
118 
103 
107
85 
34 
38 
29 
30 
30
90 
 0 
 0 
 0 
0
COEFFICIENTS OF UTILIZATION
ZONAL CAvITY METHOD * EFFECTIvE FLOOR CAvITY REFLECTANCE = .20
  
 
 
 
  
 
 
  
 
  
 
     80  
  
               70   
  
 
50
Wall Reflectance
 
70  50  30  10  70  50 
30  10  50  30 
10
  0  .81  .81  .81  .81  .79  .79  .79  .79  .75  .75  .75
  1  .74  .71  .69  .66  .73  .70  .67  .65  .67  .65  .63
  2  .68  .62  .58  .54  .66  .61  .57  .54  .59  .55  .52
  3  .62  .55  .50  .46  .60  .54  .49  .45  .52  .48  .44
  4  .57  .49  .43  .39  .55  .48  .43  .38  .46  .41  .38
  5  .52  .43  .37  .32  .50  .42  .36  .32  .41  .36  .32
  6  .48  .38  .32  .28  .46  .38  .32  .28  .36  .31  .27
  7  .44  .34  .28  .24  .43  .34  .28  .24  .33  .28  .24
  8  .40  .31  .25  .21  .39  .30  .25  .21  .29  .24  .21
  9  .37  .28  .22  .18  .36  .27  .22  .18  .26  .21  .18
 10  .34  .25  .19  .16  .33  .25  .19  .16  .24  .19  .16
     
 
 
 
 
 
 
DETERMINED IN ACCORDANCE WITH CuRRENT IES PuBLISHED PROCEDuRES
LuMINAIRE INPuT WATTS = 65.0
Room Cavity Ratio
ZONE 
LUMENS 
% LAMP 
% LUMINAIRE
0-30 
914 
17.59 
25.92
0-40 
 1511 
29.06 
42.82
0-60 
 2737 
52.64 
77.56
0-90 
 3529 
67.87 
100.00
40-90 
2017 
38.81 
57.18
60-90 
 791 
15.23 
22.44
90-180 
.00 
.00
0-180 
3529 
67.87 
100.0
DISTRIBUTION
CANDLEPOWER CURVE 228
Performance
CANDLEPOWER
REPORT NO: LSCD076
CAT. NO: QCE2GPFOS228
2 28W T5 Fluorescent Lamps at 2600 lumens. 
Efficiency: 67.9% 
Candela at Nadir: 1163cd
90°
90°
180°
400
800
1200       
 
 
 
  
ZONE  
 
 
 
 
 
DEG   
 
ALONG  22.5 
45 
67.5 
ACROSS
 
 
 
 
 
 
  0 
1904 
1904 
1904 
1904 
1904
  5 
1900 
1896 
1894 
1896 
1891
10 
1867 
1872 
1879 
1872 
1867
15 
1821 
1834 
1839 
1840 
1839
20 
1760 
1769 
1783 
1792 
1795
25 
1681 
1695 
1718 
1735 
1738
30 
1596 
1604 
1646 
1667 
1674
35 
1473 
1504 
1547 
1587 
1597
40 
1344 
1381 
1445 
1494 
1507
45 
1198 
1244 
1325 
1380 
1404
50 
1038 
1095 
1194 
1260 
1293
55 
873 
941 
1059 
1147 
1171
60 
698 
784 
930 
1014 
1046
65 
533 
639 
780 
867 
874
70 
386 
501 
630 
671 
658
75 
259 
365 
437 
401 
362
80 
147 
231 
185 
164 
168
85 
47 
62 
49 
60 
58
90 
0
COEFFICIENTS OF UTILIZATION
ZONAL CAvITY METHOD * EFFECTIvE FLOOR CAvITY REFLECTANCE = .20
  
 
 
 
  
 
 
  
 
  
 
     80  
  
               70   
  
 
50
Wall Reflectance
 
70  50  30  10  70  50 
30  10  50  30 
10
  0  .86  .86  .86  .86  .84  .84  .84  .84  .80  .80  .80
  1  .79  .76  .73  .70  .77  .74  .71  .69  .71  .69  .67
  2  .72  .66  .62  .58  .70  .65  .61  .57  .62  .59  .56
  3  .66  .59  .53  .49  .64  .57  .52  .48  .55  .51  .47
  4  .60  .52  .46  .41  .59  .51  .46  .41  .49  .44  .40
  5  .55  .46  .39  .35  .53  .45  .39  .35  .43  .38  .34
  6  .51  .41  .35  .30  .49  .40  .34  .30  .39  .34  .30
  7  .46  .37  .31  .26  .45  .36  .30  .26  .35  .30  .26
  8  .43  .33  .27  .23  .42  .32  .27  .22  .31  .26  .22
  9  .39  .30  .24  .19  .38  .29  .23  .19  .28  .23  .19
 10  .37  .27  .21  .17  .36  .26  .21  .17  .26  .21  .17
     
 
 
 
 
 
 
DETERMINED IN ACCORDANCE WITH CuRRENT IES PuBLISHED PROCEDuRES
LuMINAIRE INPuT WATTS = 96.2
Room Cavity Ratio
ZONE 
LUMENS 
% LAMP 
% LUMINAIRE
0-30 
1489 
19.10 
26.58
0-40 
2452 
31.44 
43.77
0-60 
4393 
56.33 
78.40
0-90 
5603 
71.84 
100.00
40-90 
3150 
40.40 
56.23
60-90 
1210 
15.52 
21.60
90-180 
 0 
 .00 
 .00
0-180 
5603 
71.84 
100.00
DISTRIBUTION
CANDLEPOWER CURVE 328
Performance
CANDLEPOWER
REPORT NO: LSCD077
CAT. NO: QCE2GPFOP328
3 28W T5 Fluorescent Lamps at 2600 lumens. 
Efficiency: 71.8% 
Candela at Nadir: 1904cd
90°
90°
180°
800
1600
2400