Moyer Diebel DF-M6 사용자 설명서

다운로드
페이지 46
11
OPERATION (Cont’d)
To Adjust Rinse Agent Injector:
1.
When a new rinse agent container is installed, push the prime button in and hold until the
rinse injector feed tube is full.
2.
Start the washer. Take a sample from the final rinse spray  tubes.
3.
To increase the volume of rinse agent, turn the adjustment screw clockwise.
4.
To decrease the volume of rinse agent, turn the adjustment screw counter-clockwise.
NOTE: 
To meet the requirements of N.S.F. standards, Iodophor in a concentration of 12.5 ppm or
chlorine at 50 ppm must be used in the final rinse.
OPERATION