Testing Procedures 
 
!
WARNING
 
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to oven before servicing, 
unless testing requires power and/or gas. 
16 
16023417 
©2004 Maytag Services 
Component Testing 
Illustration Component 
Test 
Procedure 
Results 
 
 
 
Oven light socket 
Remove one wire from receptacle 
and test resistance of terminals........
Measure voltage at oven light...........
 
Indicates continuity with bulb screwed in. 
120 VAC, see wiring diagram for terminal 
identification. 
If no voltage is present at oven light, check 
wiring or light switches. 
 
 
Autolatch assembly 
with switch 
Disconnect wires and test for 
continuity per wiring diagram. 
 
Refer to Parts Manual for correct 
autolatch switch associated with the 
correct manufacturing number. 
See wiring diagram for schematic layout. 
Access assembly by removing left side 
panel. 
5 K btu 
9.2 K btu (2) 
16 K btu  
12 K btu  
270
° valve 
 
Verify gas is supplied. 
 
Adjust set screw for simmer control. 
 
 
 
Spark 270
° switch 
Test for voltage at terminals .............
 
Disconnect wiring and check for 
continuity in LITE position.................
120 VAC 
 
 
Continuity in LITE position. 
 
 
Spark ignition 
electrode 
Test for resistance of spark lead ......
 
Test ignitor to chassis.......................
Continuity 
 
No continuity from ignitor to chassis. 
5 K btu 
9.2 K btu (2) 
16 K btu 
12 K btu  
Top surface burner 
 
Verify gas is supplied .......................
 
Verify burner cap is positioned 
correctly. 
 
Check for obstructions in burner ports. 
 
L
A
B
A1
B1
N
 
Spark module 4 + 0 
Test for voltage at terminals L and N
 
Check polarity and ground................
120 VAC 
 
See wiring diagram 
 
 
Temperature sensor 
Measure resistances ........................
 
Approximately 1100 
Ω at room temperature 
75
°F. 
 
 
Pressure regulator 
Verify gas pressure (W.C.P.). 
 
If on LP service verify proper gas 
supply conversion. 
5" Natural 
10" LP/propane 
 
 
Door plunger switch 
Remove switch from unit and 
measure the following points: 
C NO.............................................
 
 
Plunger in infinite, Plunger out continuity. 
 
 
Bake element, Upper 
Disconnect wire leads to element 
and measure resistance of terminals
Measure voltage at bake element.....
 
Approximately 31.0 
Ω, if not replace. 
240 VAC, see wiring diagram for terminal 
identification. If no voltage is present at 
bake element check wiring. 
 
 
Bake element, Lower 
Disconnect wire leads to element 
and measure resistance of terminals
Measure voltage at bake element.....
 
Approximately 21.3 
Ω, if not replace. 
240 VAC, see wiring diagram for terminal 
identification. If no voltage is present at 
bake element check wiring. 
 
 
Broil element, Upper 
Disconnect wire leads to element 
and measure resistance of terminals
Measure voltage at broil element......
 
Approximately 25.4 
Ω, if not replace. 
240 VAC, see wiring diagram for terminal 
identification. If no voltage is present at 
broil element check wiring.