3.3  Burner and Nozzle Data Tables (90 cm Models) 
 
 
 
 
Burner
 
Rated 
heat 
capacity 
(kW) 
 
BOTTLED GAS - G30/G31 30/37 mbar 
 
 
Nozzle 
diameter 
1/100 mm 
By-pass 
mm 
1/100 
Reduced 
heat capacity 
(W) 
Flow-rate 
g/h G30 
Flow-rate 
g/h G31 
Auxiliary 
50 
30 
350 
73 
71 
Semi-rapid 
1.75 
65 
33 
450 
127 
125 
Rapid 
85 
45 
800 
218 
214 
Triple Flame 
3.2 
91 
65 
1500 
233 
229 
Fish 
1.9 
68 
45 
800 
138 
136 
Oven 
3.2 
87 
48 
850 
233 
229 
Maxi oven 
5.2 
110 
59 
1200 
378 
371 
Grill 
2.9 
87 
// 
// 
218 
214 
Maxi grill 
4.0 
100 
// 
// 
291 
286 
 
 
Burner
 
Rated 
heat 
capacity 
(kW) 
 
TOWN GAS – G110  8 mbar 
 
 
Nozzle diameter 
1/100 mm 
Reduced heat capacity 
(W) 
Auxiliary 
145 
350 
Semi-rapid 
1.75 
190 
450 
Rapid 
260 
800 
Triple Flame 
3.5 
290 
1500 
Fish 
1.9 
190 
800 
G110 gas cannot be used in models with gas oven. 
The data for town gas refer to category III 1a2H3+ appliances.
 
 
 
 
Burner
 
Rated 
heat 
capacity 
(kW) 
 
NATURAL GAS - G20 20 mbar 
 
 
Nozzle diameter 
1/100 mm 
Reduced heat capacity 
(W) 
Auxiliary 
72 
350 
Semi-rapid 
1.75 
97 
450 
Rapid 
115 
800 
Triple Flame (4) 
3.5 
133 
1500 
Triple Flame (8) 
3.5 
140 
1500 
Fish 
1.9 
94 
800 
Oven 
3.2 
130 
850 
Maxi oven 
5.2 
164 
1200 
Grill 
2.9 
130 
// 
Maxi grill 
4.0 
150 
//