5.2  Adjusting for bottled gas 
Undo the screw C and push the air regulator 
D fully down. 
Remove the nozzle E with a 7 mm spanner 
and fit the suitable one, following the 
instructions in the tables referring to the type 
of gas to be used. The nozzle must not be 
tightened with a torque of more than 3 Nm
Regulate the air flow by sliding the regulator D 
along until the distance “X” stated in point "5.5 
Adjusting the primary air flow” is obtained.  
Fix the regulator D by tightening the screw C
 
 
 
Burner
 
Rated 
heat 
capacity 
(kW)
 
 
Bottled gas – G30/G31  30/37 mbar
 
 
 
Nozzle 
diameter 
1/100 mm
By-pass 
mm 
1/100 
Reduced 
heat 
capacity 
(W)
 
Flow 
rate g/h 
G30
 
Flow 
rate g/h 
G31
 
Auxiliary
 
1.05 
48 
30 
400 
76 
75 
Semi rapid
 
1.7 
62 
32 
450 
124 
121 
Rapid
 
3.0 
80 
1050 
218 
214 
50 
Ultra Rapid 
 
 5.0 
108 
63 
1600 
363 
357 
 
 
5.3  Adjusting for natural gas 
The appliance is tested with G20 (2H) natural gas at the pressure of 20 mbar. To return the 
appliance to the condition required to use this type of gas, proceed as described in point “5.2 
Adjusting for bottled gas” but select the nozzles and adjust the primary air flow for natural gas, 
as indicated in the table below and in point “5.5 Adjusting the primary air flow”. 
 
Rated heat  
Burner
 
Capacity (kW)
Natural gas - G20 20 mbar
 
 
 
Nozzle diameter 
Reduced heat capacity 
1/100 mm
 
(W)
 
Auxiliary
 
1.05 
73 
400 
Semi rapid
 
1.7 
92 
450 
Rapid
 
3.0 
123 
1050 
Ultra Rapid
 
5.0 
165 
1400