Smeg PA106SX 사용자 설명서

다운로드
페이지 20
 
 
Instructions for the installer 
 
13
 
 
 
5.2  Adjustment for LPG (Propane) 
 
 
 
 
  Check that the connection has been made as described in
the “Gas connection” section. 
Undo the screw “C” and push the air regulator “D” fully 
down. Use a spanner to remove the nozzles “E” and fit 
those of suitable type following the instructions given in the
tables for bottled gas LPG (Propane) 2.75 kPa. The nozzle
must not be tightened to a torque of over 3 Nm
 
LPG (Propane) – 2.75 kPa 
Burner 
 
 
Nominal gas 
Injector 
consumption (MJ/h) 
(mm) 
4.2
 
0.54
 
Auxiliary (1) 
5.9
 
0.65
 
Semi rapid (2) 
8.6
 
0.78
 
Medium rapid (3) 
9.5
 
0.85
 
Large rapid (4) 
0.82 
UR (5) 
13.5 
0.54 
 
 
 
CAUTION: for references A and B on the left UR 
and right UR burners, see drawings at side.
 
             
 
 
 
 
 
 
5.3  Adjustment for natural gas 
 
 
 
 
  The hob has been adjusted for natural gas at a pressure of 1.0kPa. 
To allow the unit to work back with this type of gas, after it has been adjusted for LPG 
(Propane), perform the same operations described in paragraph “5.2 Adjustment for
LPG (Propane)”, but refer to the following table for the proper injectors. 
 
Burner 
NG – 1.0 kPa 
 
 
Nominal gas 
Injector 
consumption (MJ/h) 
(mm) 
3.2
 
0.82
 
Auxiliary (1) 
4.8
 
1.00
 
Semi rapid  (2) 
8.6
 
1.25
 
Medium rapid (3) 
11.4
 
1.50
 
Large rapid (4) 
1.45 
UR (5) 
13.5 
0.82