Page 13
Castile & Santa Fe CE Pellet Stove 
7068-112
Figure 14.2
Vacuum inside
Exhaust Venting
The  amount  of  ash  buildup  in  the  firepot  will  be  a  good
guide  to  determine  how  often  you  should  clean  the  heat
exchangers.
WARNING
Heat exchanger cleaning rods may be warm
to the touch. For safety purposes wear
gloves.
Do not pull heat exchanger cleaning rods
while appliance is operating.
Push cleaning rods IN when done, DO NOT
leave cleaning rods OUT. Injury can occur.
7.  Cleaning Heat Exchanger Chambers & Drop Tube
•  Frequency:
Weekly or every 15 bags or more fre
quently depending on ash build-up
•  By: Homeowner
NOTE:  Hearth & Home Technologies recommends to 
use  a  heavy  duty  vacuum  cleaner  specifically 
designed for solid fuel appliance cleaning.
9.  Cleaning the Exhaust Path
•  Frequency:
Every 25 bags or monthly or more fre
quently depending on ash build-up.
•  By: Homeowner
 a. Appliance must be completely cool.
 b.  Open  cast  hinge  face.    Remove  baffle  and  right
brick and thoroughly vacuum the area and continue
throughout the rest of the firebox.
 c.  Replace right brick and baffle and close cast hinge
face.
10. Cleaning the Hopper
•  Frequency:
Monthly or after burning 50 bags of fuel
•  By: Homeowner
After burning approximately 1 ton of fuel you will need
to clean the hopper to prevent sawdust build-up.
A  combination  of  sawdust  and  pellets  on  the  auger
reduces the amount of fuel supply to the firepot. This
can result in nuisance shutdowns and mis-starts.
 a.  The  appliance  must  be  in  complete  shutdown.
Allow the appliance to completely cool down.
b.  Empty the hopper of any remaining pellets.
c.  Vacuum the hopper and feed tube.
a. Allow the appliance to completely cool down before
pulling the cleaning rods.
  Turn the thermostat on and
then immediately off to start the exhaust blower on its
cycle time. It will pull fly ash out the exhaust instead
of into the room.
 b.  Locate the 2 exposed rods directly underneath the heat
exchanger tubes.
Figure 14.1. 
 c. To  clean,  pull  the  rods  straight  out  until  it  stops,
approximately 203mm. Slide the rods OUT and IN a
couple of times.
Figure 14.1
Cleaning 
Rods
10 Heat Exchanger Tubes
8.  Door Latch Inspection
•  Frequency:
Prior to heating season or monthly during
heating season
•  By: Homeowner
The door latch is non-adjustable but the gasketing between
the glass and firebox should be inspected periodically to make
sure there is a good seal.