GE WV-2HSG 사용자 설명서

다운로드
페이지 4
M O D E L
W V- 2 H S G
G R I D D L E ,   2   S P I R A L   E L E M E N TS
*RW Models include optional RW-26 built-in standard double drawer warmers.
NOTE: Specifications are subject to change without notice. 
SPECIAL ENVIRONMENTAL NOTICE: The hood system is designed to reduce odor emissions but will not eliminate odors. 
Air exchange at the installation site must comply with requirements of the local jurisdictional authority. To ensure dilution of 
odor build-up, minimum recommendation is 400 cubic feet of fresh air per minute both in and out of the area.
D I M E N S I O N S :
INCH
(MM)
W
E L L S
  M
A N U F A C T U R I N G
MINIMUM CLEARANCE REQUIRED FROM UNIT 
TO THE NEAREST SURFACE 
  BACK 
SIDE 
BOTTOM 
TOP
 
NA 
SEE REQUIRED
 
8
 
NA 
SPACERS
 
(152) 
(203)
COOKING SURFACE ILLUSTRATION
8 INCH SPIRAL ELEMENTS
GRIDDLE: 17 1/4 X 18 1/4
AND PLUG
SUPPLY CORD
6 FT. POWER
OPENING
PANEL
CONTROL
SHIELDS
SPACERS & SIDE
6" CLEARANCE
REQUIRED
(441)
17 3/8
577
22 3/4
1076
42 3/8
688
27 1/16
(2010)
79 1/8
(771)
30 3/8
(898)
35 3/8
(914)
36
1217
47 15/16
EXHAUST
AIR
                                                                                                                                          
W V- 2 H S G   E L E C T R I C A L   S P E C I F I C AT I O N S :
    MODELS     VOLTS     WATTS  AMPS PER LINE 3 PHASE 
POWER SUPPLY CORD
                                          
 
 
L1         L2 
L3
       WV-2HSG           208            8900                21             35            24 
NEMA 15-60P
       WV-2HSG           240            11100               23             38            24 
NEMA 15-60P
   WV-2HSGRW*        208             9575                23             35            26 
NEMA 15-60P
   WV-2HSGRW*        240            12000               26             38            27 
NEMA 15-60P
M O D E L
W V- F G
G R I D D L E ,   F RY E R
*RW Models include optional RW-26 built-in standard double drawer warmers.
NOTE: Specifications are subject to change without notice. 
SPECIAL ENVIRONMENTAL NOTICE: The hood system is designed to reduce odor emissions but will not eliminate odors. 
Air exchange at the installation site must comply with requirements of the local jurisdictional authority. To ensure dilution of 
odor build-up, minimum recommendation is 400 cubic feet of fresh air per minute both in and out of the area.
D I M E N S I O N S :
E146882
LISTED
R
LISTED
R
E146882
R
STD.4
INCH
(MM)
W
E L L S
  M
A N U F A C T U R I N G
  BACK 
SIDE 
BOTTOM 
TOP
 
NA 
SEE REQUIRED
 
8
 
NA 
SPACERS
 
(152) 
(203)
(1237)
48 11/16
(441)
17 3/8
(1076)
42 3/8
(898)
35 3/8
(578)
22 3/4
(2010)
79 1/8
(914)
36
(771)
30 3/8
(687)
27 1/16
(533)
21
PANEL
CONTROL
OPENING
EXHAUST
AIR
SHIELDS
SPACERS & SIDE
6" CLEARANCE
REQUIRED
AND PLUG
SUPPLY CORD
6 FT. POWER
COOKING SURFACE ILLUSTRATION
GRIDDLE: 17 1/4 X 18 1/4
FRYER
                                                                                                                                          
W V- F G   E L E C T R I C A L   S P E C I F I C AT I O N S :
    MODELS     VOLTS     WATTS  AMPS PER LINE 3 PHASE 
POWER SUPPLY CORD
                                          
 
 
L1         L2 
L3
         WV-FG             208            10750               30             43            24 
NEMA 15-60P
         WV-FG             240            11650               26             40            24 
NEMA 15-60P
      WV-FGRW*          208            11425               32             43            26 
NEMA 15-60P
      WV-FGRW*          240            12550               28             40            27 
NEMA 15-60P
MINIMUM CLEARANCE REQUIRED FROM UNIT 
TO THE NEAREST SURFACE 
E146882
LISTED
R
LISTED
R
E146882
R
STD.4
05/02  •  REV(-)  •  PART NO. 304421-3
05/02  •  REV(-)  •  PART NO. 304421-1