Franke Consumer Products FTU 3807 I 사용자 설명서

다운로드
페이지 60
 
 
 
 
 
EN 
 
2
6
 
26 
Activated charcoal filter (Recirculation version) 
•  The  filter  is  not  washable  and  cannot  be  regenerated.  It  must  be  replaced  when  led  S1 
flashes  or  at  least  every  4  months.  The  alarm  signal  will  only  light  up  when  the  extractor 
motor is switched on. 
Alarm signal activation 
•  In Recirculation version Hoods, the Filter saturation alarm can be enabled on installation or 
at a later date. Turn the Lights and the suction Motor off. 
•  Disconnect the Hood using the Main switch or the double-pole switch on the mains power 
supply. 
•  Restore the connection by pressing and holding T1. 
•  Release the button.  All five LEDs are turned on 
•  Within 3 seconds press T1 until LEDs  T1 and T4 flash in confirmation: 
  LED flashes twice - Activated charcoal filter saturation alarm ENABLED 
  LED flashes once - Activated charcoal filter saturation alarm DISABLED 
 
REPLACING
 
Alarm signal reset 
•  Turn the Lights and the suction Motor off. 
•  Press T3 for at least 4 seconds, until indicators T1 and T4 flash 
to confirm. 
Replacing the Filter 
•  Open the lighting unit by pulling on the nocth
 
•  Remove the metal grease filters
 
•  Remove  the  saturated  activated  carbon  filter  by  releasing  the 
fixing hooks 
•  Fit the new filter by hooking it into its seating 
•  Replace the metal grease filters and the lighting unit. 
 
 
Lighting 
LIGHT REPLACEMENT 
20 W halogen light. 
•  Extract the lamp from the lamp holder by pulling gently. 
•  Replace  with  another  of  the  same  type,  making  sure  that  the 
two pins are properly inserted in the lamp holder socket holes.