Franke Consumer Products FDMO 607 I 사용자 설명서

다운로드
페이지 64
 
 
 
 
EN 
 
1
2
 
12 
Ducted version air exhaust system Connection 
When installing the ducted version, connect the hood to the 
chimney using either a flexible or rigid pipe ø 150 or 120 mm, 
the choice of which is left to the installer. 
•  To install a ø 120 mm air exhaust connection, insert the re-
ducer flange 9 on the hood body outlet. 
•  Fix the pipe using the pipe clamps 25 provided.  
•  Remove any activated charcoal filters. 
 
 
9
ø 150
ø 120
25
25
AIR OUTLET – RECIRCULATION VERSION 
•  Fasten the Air Outlet Connector 15 to the upper frame using 
the 2 knobs 24
•  Attach the Air Outlet Connector Flange 14 to the Air Outlet 
Connector 15
•  Connect the two outlets using the Air Outlet Connector Pipe 
29
 
14
15
24
15
14
15
29