Lincoln Series 1200 사용자 설명서

다운로드
페이지 112
Impinger I -–1000 Series Service Manual - International 
37 
 
Thermocouple Probe 
Place your pyrometer thermocouple into the center 
between fingers T2 and T3 in the oven. For ovens 
with Mechanical Measure D.C. millivolts at 
Thermostat terminals 9 and 10 on the time/temp 
display. See thermocouple chart on page 59 for 
proper readings. Replace thermocouple if proper 
readings not achieved.  If readings are correct on 
the thermocouple, replace time/temp display. 
For ovens with 
Electronic Thermostat 
 
Connect temperature meter to thermocouple at 
terminals 9 & 10 on back of the time/temp display. 
(Be sure to maintain proper polarity on 
thermocouple connections.)  Compare actual oven 
temperature with the readings at the time/temp 
display.  If the temperature readings match, 
recalibrate or replace time/temp display.  If the 
readings do not match, replace thermocouple 
probe. 
Erratic time/temp 
display 
 
If strange or unusual behavior is experienced such 
as a rolling of numbers, lock up at a given number, 
first check for a display circuit lock up. This can be 
caused by a voltage spike or surge. To eliminate 
this condition remove power from the time/temp. 
display by shutting off the main fan switch, or if 
display stays on, (older models) circuit breaker 
interruption may be required. This should eliminate 
the problem. If the problem continues, jumper the 
two fuses in the red wires leading from the 12.6 
VAC transformer to the display. If this does not 
solve the problem, it may be coming in through the 
commercial power lines. Suggest that customer 
contact his power company for evaluation. 
Temp Display 
inaccurate erratic, or 
inoperative 
 
Perform the power supply check, the thermistor 
probe check, and then perform the time/temp 
simulator test. Refer to page 72 for instructions. 
Remember, when using the time/temp simulator, 
remove all the leads from the back of the display 
except the 3 power leads. After completion of this 
test and if reinstalling back into the oven, the dip 
switches must be reset for oven operation. 
Time display 
inaccurate erratic, or 
inoperative(S/N 
Q4615-Q14970) 1000 
Series(S/N Q4615-
Q14790) 1200 Series 
 
Perform all checks as in the above evaluation. If 
the time check is okay, refer to the next section 
optical encoder. 
 
Optical Encoder 
The above time/temp test should have already 
been performed. Remove dust cover from the 
gearmotor and inspect the coupling and encoder 
disc. The coupling set screws should be tight and 
not slipping on the motor shaft or the tach. 
generator shaft. The encoder disc should be firmly 
attached to the coupling and not warped. Check the 
positioning of the optical encoder disc. The disc 
should not be touching the optical encoder 
assembly and the encoder assembly should be 
mounted so it is squarely facing the coupling shaft. 
This is to allow the infrared beams to be broken by 
the encoder disc. If all this is okay, then replace the 
optical encoder assembly.