Impinger I -–1000 Series Service Manual - International 
48 
Spark Generator 
After a pre-purge time of 30 to 60 seconds after 
blower motor starts, check for 220 VAC to spark 
generator. If voltage is not present, check reset 
button on ignition control. If voltage is present, 
visually check for spark at ignitor head. 
Ignitor/Sensor Assembly 
Check for visible damage to ignitor/sensor 
assembly. If there is no visible damage to the 
components, and no spark, replace the spark 
generator. If there is visible damage to the ignitor 
sensor assembly, replace. Also check for frayed or 
damaged wire in burner tube. 
Gas Valve 
Check for 220 VAC supply to gas valve. If no 
voltage present, check reset button on ignition 
control, check all connections for tightness. If there 
is no voltage at gas valve, replace ignition control. 
If there is voltage present, check for gas pressure 
at gas pressure tap located in gas piping. If there is 
no gas pressure, replace gas valve. 
 
If the ignition control is energized, and the gas 
valve and ignitor circuits are energized, visually 
check for pilot flame. This may be done by opening 
the small inspection door on the end of the burner, 
or by opening the main oven door and looking 
under the lower finger housings on the right side of 
the oven. If no pilot flame is visible, check the 
following. 
Pilot Tube 
Check for gas pressure at pilot tube. Disconnect 
pilot tube at burner and connect manometer to pilot 
tube. If no gas pressure is present, check for 
blockage in pilot tube. If these are clear, and there 
is gas supplied to the oven, replace the gas valve. 
Pilot Orifice 
If there is gas pressure at the pilot tube, check the 
pilot orifice for obstructions. Replace as needed. 
No Pilot 
Burner Ignitor 
Check the burner ignitor head for any obstructions, 
also check for frayed or broken wire, any type of 
damage to spark gap (.100 in 2.5 mm).If there is 
visible damage, replace ignitor assembly. 
Pilot flame, but burner 
will not stay ignited 
Flame Sensor 
(There should be a visible pilot flame at this time). 
To check for flame sensor operation, connect a 
digital multimeter. (Capable of measuring D.C. 
microamperes) between the flame sensor wire and 
the ignition control. NOTE: This is current 
measurement and the meter must be connected in 
series. Proper current readings should be 
Honeywell 2-4 micro amp D.C., Landis & Gyr. 3 
micro amp D.C. If these readings are not achieved, 
replace ignitor/sensor assembly. Also check for any 
type of damage to flame sensor wire and 
connections. 
 
Ignition Control 
If there is sufficient flame sensor current, but the 
burner will not remain ignited, check reset button on 
ignition control. 
Indicator light is on but 
no main flame, (Model 
1046-1047) 
Gas Control Relay 
Check for 220 VAC to relay coil. If no voltage is 
present, trace wiring back to ignition control. If 
voltage is present, check to insure contacts are 
closing.