SERVICE (cont.)
EMI FILTER (230 Volt FMD DBC-3)
FIG. 20 EMI FILTER
Location:
 
The EMI Filter is located on the rear of the dispenser 
base on FMD DBC-3.
Test Procedure:
1.  Disconnect the dispenser from the power source.
2.  Disconnect the two black wires and two white 
wires on the EMI Filter from the EMI Filter wiring 
harness.
3.  Check for resistance between the two black leads 
on the EMI Filter.
If resistance is present as described the EMI Filter is 
operating properly.
If resistance is not present as described, replace the 
EMI Filter.
Removal and Replacement:
1.  Disconnect the wires from the EMI Filter.
2.  Remove the two #8-32 screws and nuts securing 
the EMI Filter.
3.  Remove and discard EMI Filter.
4.  Install new EMI Filter using two #8-32 screws and 
nuts to secure EMI Filter to its former location.
5.  Refer to schematic wiring diagrams when recon-
necting the wires.
FIG. 21 EMI FILTER CONNECTORS
118.0 kΩ - 118.5 kΩ
Across either pair