KitchenAid W10526086A 사용자 설명서

다운로드
페이지 40
19
Natural Gas Conversion
1. Turn manual shutoff valve to the closed position.
2. Unplug range or disconnect power.
To Convert Gas Pressure Regulator
1. Locate gas pressure regulator at the rear of the range.
IMPORTANT: Do not remove the gas pressure regulator.
2. Unscrew the regulator cap and remove the plastic cover.
3. Flip the regulator cap over and replace the plastic cover.
4. Screw the regulator cap securely back into place. Do not 
overtighten.
To Convert Surface Burners
1. If the burner grates are installed, remove them.
2. Remove the burner caps.
3. Using a Phillips or T20
®
 Torx
®† 
screwdriver, remove the burner 
base.
A. To range
B. Shutoff valve (closed position)
C. Gas supply line
A. Gas pressure regulator
WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Install anti-tip bracket to floor or wall per installation 
instructions.
Slide range back so rear range foot is engaged in the 
slot of the anti-tip bracket.
Re-engage anti-tip bracket if range is moved.
Do not operate range without anti-tip bracket installed 
and engaged.
Failure to follow these instructions can result in death 
or serious burns to children and adults.
A
B
C
A
A. Plastic cover
B. Regulator cap
A. LP gas position
B. Natural gas position
C. Plastic cover
A. Burner cap
B. Gas tube opening
C. Burner base screws
D. Burner base
A
B
A
B
C
A
B
C
D